{"id":42,"date":"2025-01-22T14:57:38","date_gmt":"2025-01-22T14:57:38","guid":{"rendered":"http:\/\/atnano.sim.tuiasi.ro\/?page_id=42"},"modified":"2025-10-16T12:27:25","modified_gmt":"2025-10-16T12:27:25","slug":"echipamente","status":"publish","type":"page","link":"https:\/\/atnano.sim.tuiasi.ro\/en\/echipamente\/","title":{"rendered":"Equipment"},"content":{"rendered":"<figure class=\"wp-block-image size-large is-style-default\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"576\" src=\"http:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2-1024x576.png\" alt=\"\" class=\"wp-image-144\" srcset=\"https:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2-1024x576.png 1024w, https:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2-300x169.png 300w, https:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2-768x432.png 768w, https:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2-18x10.png 18w, https:\/\/atnano.sim.tuiasi.ro\/wp-content\/uploads\/2025\/03\/atnano-2.png 1280w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><em>Services:<\/em><\/strong><\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Nanofluids manufacturing<\/li>\n\n\n\n<li>Study of electrical properties of nanofluids in heating \/ cooling mode<\/li>\n\n\n\n<li>Study of solutions PH<\/li>\n\n\n\n<li>Study of thermal conductivity of solids, fluids and colloids<\/li>\n\n\n\n<li>Study of thermal conductivity in heating \/ cooling mode<\/li>\n\n\n\n<li>Heating operations up to 1200 \u00b0C<\/li>\n\n\n\n<li>Simulation of heating processes and nanofluids behavior<\/li>\n<\/ul>\n\n\n\n<hr class=\"wp-block-separator has-alpha-channel-opacity\"\/>\n\n\n\n\n<\/head>\n<body>\n\n<h2>Equipment and characteristics<\/h2>\n\n<table>\n    <thead>\n        <tr>\n            <th>Test type<\/th>\n            <th>Equipment<\/th>\n            <th>Year<\/th>\n            <th>Equipment characteristics<\/th>\n        <\/tr>\n    <\/thead>\n    <tbody>\n        <tr>\n            <td data-label=\"Tip test\">Sample weighting<\/td>\n            <td data-label=\"Echipament\">KERN ADJ 100-4 (Kern, Germany)<\/td>\n            <td data-label=\"An\">2023<\/td>\n            <td data-label=\"Caracteristici echipament\">KERN ADJ: Automatic internal adjustment in the case of a change in temperature \u2265 2 \u00b0C or time controlled every 3 h, guarantees high degree of accuracy and makes the balance independent of its location of use\nWeighing capacity (max) 120g, Readability 0.1 mg, Reproducibility 0.2 mg, Linearity +\/- 0.4 mg, Stabilization time 4 sec, adjusting weight internal, accuracy: 1\u00d710\u22123 g.<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Sample homogenization<\/td>\n            <td data-label=\"Echipament\">Ultrasonic homogenizer GETI GUC02A (TIPA, Czech Republic)<\/td>\n            <td data-label=\"An\">2022<\/td>\n            <td data-label=\"Caracteristici echipament\" class=\"translation-block\">Power of 60 W and a frequency of 40 kHz.\nHeating temperature setting: 20-80\u2070C\nCapacity 2L, heating power 100 W, Time setting 1-20 min<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Sample homogenization<\/td>\n            <td data-label=\"Echipament\">VWR Ultrasonic Cleaner USC100TH, 142-6045 (VWr International BVBA, Leuven, Austria)<\/td>\n            <td data-label=\"An\">2022<\/td>\n            <td data-label=\"Caracteristici echipament\">Ultrasonic energy with approx. 45kHz<br>Built-in liquid heater<br>Heater power 60W<br>Tank capacity 0.8L<br>Inner dimensions: 190x85x60 mm<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Sample homogenization<\/td>\n            <td data-label=\"Echipament\">AREX-6 Digital PRO Heating Magnetic Stirred Code: SA20500460 (VELP Scientifica Srl, Italy)<\/td>\n            <td data-label=\"An\">2023<\/td>\n            <td data-label=\"Caracteristici echipament\">Digital hot plate stirrer with white LED display and a set of icons providing precise settings and clear readout of the working conditions.<br>The fast heating, 135 mm diameter CerAlTop\u2122 plate protects from chemicals, scratches and enhances the lifetime of the unit. Enhanced kinetics and programmable operations thanks to integrated timer and auto-reverse.<br>Volume (H\u2082O) 20 L\nStirring speed: From 30 to 1700 rpm, Temperature range: From room temperature to 370 \u00b0, External connection Pt 100 Probe, External connection VTF<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Sample homogenization<\/td>\n            <td data-label=\"Echipament\">Digital thermoregulator VTF system (VELP Scientifica Srl, Italy)<\/td>\n            <td data-label=\"An\">2023<\/td>\n            <td data-label=\"Caracteristici echipament\">Temperature range: From -10 \u00b0C to 300 \u00b0C<br>Timer From 0 minute to 24:59 hours<br>Temperature control with an accuracy of \u00b1 0.5 \u00b0C<br>It automatically adjusts the thermoregulation to different factors such as power, load and thermal dispersion.<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Sample homogenization<\/td>\n            <td data-label=\"Echipament\">ZX4 Advanced IR Vortex mixer (VELP Scientifica Srl, Italy)\nCode: F202A0280<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">ZX4 Vortex mixer is highly innovative and patented IR technology reduces repetitive strains. IR sensor and continuous mode available. Large choice of complementary accessories to accommodate tubes, plates and flasks.<br>The VELP IR sensor uses an infrared system (IR) to detect the presence of the tube and automatically starts vibrating. The technopolymer housing and zinc base ensure optimum chemical resistance and excellent stability on the bench.<br>Stirring speed Up to 3000 rpm, Patented IR Sensor, 100\u00f7240 V \/ 50-60 Hz<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">pH test<\/td>\n            <td data-label=\"Echipament\">Edge Multiparameter HI 2030 (Hanna Instruments, Romania).<\/td>\n            <td data-label=\"An\">2022<\/td>\n            <td data-label=\"Caracteristici echipament\">HI11310: Digital pH Electrode with integrated temperature sensor. Calibration can be performed using up to five calibration buffers.<br>The calibration buffer list includes: pH 1.68, 4.01 (pH 3.00), 6.86, 7.01, 9.18, 10.01 and 12.45. \nAll pH measurements will display, log and export with 0.01 pH resolution.\nAdjustable resolution for pH and EC measurements\nAuto parameter recognition<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Electrical conductivity<\/td>\n            <td data-label=\"Echipament\">Edge Multiparameter HI 2030 (Hanna Instruments, Romania).<\/td>\n            <td data-label=\"An\">2022<\/td>\n            <td data-label=\"Caracteristici echipament\">HI763100: Digital 4 ring conductivity probe with integrated temperature sensor. \nAdjustable resolution for pH and EC measurements\nAuto parameter recognition.<br>Hanna Instruments Conductivity standards are available at 84 \u03bcS\/cm, 1413 \u03bcS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm and are used for the cell factor calibration.<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">ROTAVISC lo-vi viscometer (IKA Werke GmbH &amp; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">Viscosity Measuring Range 6000000 mPas, Viscosity Accuracy (FSR) 1 %, Viscosity Repeatability (FSR) 0.2 %, Spring Torque 0.0673 mNm, Measuring Shaft Series Set SP 1, Motor Rating Output 4.8 W, Overload Protection yes, Rotation Direction cda, TFT Display, Speed Range 0. 01 - 200 rpm, Accuracy speed setting \u00b10.01 rpm, Speed adjustment TFT, Torque display yes, Torque measurement yes, Timer yes, Time setting range 0.017 - 6000 min, Temperature measurement resolution 0.1 K, Connection for temperature sensor ext. PT 100, Operating mode timer and continuous operation, Calibration option yes, Emitted density 9999 kg\/dm3, Working temperature - 100 - 300 \u00b0C, Stand mounting extension arm, Support rod diameter (with integrated stand mounting) 16 Mm, Telescope stand stroke 200 mm, Coupling with connection 12 Mm, Base container volume 600 Ml, Rotastand stand, Max. stroke 61 Mm, Diameter 16 Mm, Dynamic load 5 Kg, Relative humidity 80 %, Interface RS 232 yes, Interface USB USB-B, Voltage 100 - 240 V<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">Laboratory software for ROTAVISC (IKA Werke GmbH &amp; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">IKA Werke GmbH &#038; Co. KG<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">Bath type CBC VISC lite for ROTAVISC (IKA Werke GmbH &amp; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">Type: Refrigerating and heating circulator, Class designation according to DIN 12876 III, Identification according to DIN 12876 FL, Coolant R290, Coolant quantity 55 g, Coolant pressure max. -25\u00b0C, Temperature display yes, Temperature stability DIN 12876 (@+70\u00b0C) \u00b10.05 K, Temperature stability DIN 12876 (@-10\u00b0C) \u00b10.05 K, PID temperature control, PT1000 working temperature sensor, PT1000 safety temperature sensor, LED working temperature display, Safety temperature LED display, Display resolution 0,1 K, Set temperature resolution 0,1 K, Adjustable safety circuit 0 - 135 \u00b0C, Underlevel protection yes, Overlevel protection yes, Filling volume 5,5 - 8,5 l, Pump type Pressure\/suction pump, Pump pressure max. (delivery flow 0 liters) 0,35 bar, Pressure pump (suction side) (flow 0 liters) 0,15 bar, Max. flow (back pressure 0 bar) 18 l\/min, Pump connection M16x1, Min. bath depth 150 mm, Bath opening width 150 mm, Bath opening depth 218 mm, Total bath height 234 mm, Technical data according to DIN 12876, Permissible switch-on time 100 %, Noise level 53 dB(A), Dimensions (W x H x D) 414 x 392 x 505 mm, Weight 29 kg, Permissible ambient temperature 5 - 32 \u00b0C, Relative humidity 80 %, Protection class according to DIN EN 60529 IP 21, Interface RS 232 yes, Interface USB USB-B, Voltage 230 V, Frequency 50\/60 Hz, Power consumption 2320 W<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">VOLS-1 low volume adapter set for Io Vi ROTAVISC (IKA Werke GmbH &amp; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">Features: Shaft geometry Cylinder, Connection thread M2.5 LH, Hook connector yes, Sample volume 6.7 ml, Flow sleeve yes, Mounting bracket yes, Sample container: Specified chamber, Working temperature max. 100 \u00b0C, Viscosity accuracy (FSR) 2 %, Viscosity repeatability (FSR) 0.2 %, FSR min. match. ROTAVISC lo-vi 1.5 mPa.s, FSR match max. ROTAVISC lo-vi 30000 mPa.s, FSR match min. ROTAVISC me-vi 16 mPa.s, FSR match max. ROTAVISC me-vi 320000 mPa.s, FSR match min. ROTAVISC hi-vi I 32 mPa.s, FSR match max. ROTAVISC hi-vi I 640000 mPa.s, Min. FSR match ROTAVISC hi-vi II 128 mPa.s, Max. FSR compatible with ROTAVISC hi-vi II 2600000 mPa.s, Material in contact with medium: stainless steel 1.4404, Dimensions (W x H x D) 300 x 110 x 275 mm, Weight 1,656 kg<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">ELVAS 1 (IKA Werke GmbH &#038; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">The extremely low viscosity adapter spindle set ELVAS-1 includes a double jacket to quickly heat up or cool down the sample as well as a coaxial cylinder system for the analysis of the sample at a specific shear rate and shear stress. This 16 ml spindle is commonly used with the ROTAVISC lo-vi and allows measurements from 1 mPas (water temperature at 20 \u00b0C). The maximum measurable viscosity is 2000 mPas.\nSpindle geometry\tCylinder\nDiameter 25.15 mm, spindle length 161 mm\nSample volume-16 ml\nWorking temperature - max.100 \u00b0C\nViscosity Accuracy (FSR)\t2 %: min. FSR match ROTAVISC lo-vi -1 mPa.s and max. FSR match ROTAVISC lo-vi - 2000 mPa.s<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Viscosity<\/td>\n            <td data-label=\"Echipament\">Heating system for ROTAVISC up to 300\u00b0C (IKA Werke GmbH &amp; Co. KG)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">Features: Sample volume min. 7 ml, Sample volume max. 13 ml, Sample container: Specified chamber, Working temperature max. 300 \u00b0C, Dimensions (W x H x D) 265 x 220 x 270 mm, Relative humidity 80 %, Protection class according to DIN EN 60529 IP 40, Interface RS 232 yes, Voltage 220 - 230 V, Frequency 50\/60 Hz, Input power 300 W, Input power max. 300 W, Standby input power 1.6 W<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Density<\/td>\n            <td data-label=\"Echipament\">Digital Densimeter DS7800: Densimeter - Set M - Complete set for manual sample feeding<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">DS7800 (measuring accuracy \u00b10.0001 g\/cm3). Specific features: For small sample volumes and high viscosity samples use Set 1 and for very viscous and aggressive samples Set 2. Control window for sample check, Injection medium suitable for cleaning until all sample residues have been dissolved and removed. Fitted with drying unit to then remove all liquid residues. Intuitive operation with touch screen display, easy adjustment and predefined scales such as density, relative density, brix, alcohol and sulfuric acid concentration. Compliant with GMP\/GLP, 21 CFR Part 11, pharmacopoeias (USP, BP, JP, Ph. Eur.), FDA, ISO, HACCP, OIML, ASTM, ICUMSA, NIST. Dimensions: 220 x 220 x 430 mm, Weight: 5.3 kg, Accessories: Desiccant cartridge; Rinse and fill pump; Standard tubing set: 4 pcs connection adapter, sample tubing, pump tubing, 10 pcs 5 ml syringe, Luer, 1 pc T; Waste container; Operating manual; Test report and calibration certificate according to N.I.S.T<br>Dimensiuni: 220 \u00d7 220 \u00d7 430 mm; Greutate: 5,3 kg<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Thermal conductivity<\/td>\n            <td data-label=\"Echipament\">C-Therm Trident Thermal Conductivity System: Basic K - TR-Trident-S11-CM (C-Therm Technologies, Canada)<\/td>\n            <td data-label=\"An\">2023<\/td>\n            <td data-label=\"Caracteristici echipament\">C-Therm software is developed for the Trident system. The MTPS method employs a single-sided sensor to directly measure thermal conductivity and effusivity of materials.\nBasic-k Module with Modified Transient Plane Source (MTPS) Sensor, Conforms to: ASTM D7984\nRecommended Applications: Aerogels, Automotive, Batteries, Composites, Insulation, Explosives, Geological, Liquids, Metals, Nanomaterials, Metal Hydrides, Nuclear, Phase Change Materials (PCMs), Polymers, Rubber, Thermal Interface Materials (TIMs) &amp; Thermoelectrics.\nThermal Conductivity Range: 0.03 to 10 W\/mK\nSensor Temperature Rating: -50\u2070C to 200\u2070C\n\"Plug &amp; Play\" calibrations to easily test insulation\/foams, liquids, powders, pastes, polymers, ceramics &amp; composites up to 10 W\/mK.<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Thermal conductivity<\/td>\n            <td data-label=\"Echipament\">MP-2 Platform for thermal conductivity (Thermtest, Canada)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">Measurement Capabilities: Bulk Properties<br>The thermal conductivity range depends on the type of sensor used.<br>Controller MP-2 features: Integrated intelligent software for thermal conductivity Desktop utility for download - export to Excel Automatic test programming Temperature logging Raw data logging Battery or USB powered<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Thermal conductivity<\/td>\n            <td data-label=\"Echipament\">MTPS sensors (Thermtest, Canada)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">MTPS sensor Property: Thermal conductivity, 0.029 to 20 W\/m\/K (5%) Standards: ISO 22007-2 modified Materials: Solids, powders and pastes (polymers and composites)<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Thermal conductivity<\/td>\n            <td data-label=\"Echipament\">Sensor THW-L3 (40 mm), (Thermtest, Canada)<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\">THW-L3 sensor (40 mm) Property: Thermal conductivity (5%) Standards: ASTM D7896-19<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Temperature control<\/td>\n            <td data-label=\"Echipament\">VTF Digital thermoregulator Fuzzy logic (VELP Scientifica Srl, Italy)<\/td>\n            <td data-label=\"An\">2023<\/td>\n            <td data-label=\"Caracteristici echipament\">The VTF thermoregulator guarantees premium performance in terms of temperature control with an accuracy of \u00b1 0.5 \u00b0C. It automatically adjusts the thermoregulation to different factors such as power, load and thermal dispersion.<br>Timer From 0 minute to 24:59 hours, Type of thermoregulation: Fuzzy Logic, Temperature range 0..+50\u2070C, Storage temperature range -10\u2026+60\u2070C, Construction material: Technopolymer\nTemperature setting (interval): From -10 \u00b0C to 300 \u00b0C, Type of probe: Pt100, 250 mm length, Continuous mode\/ Remaining time reading: possible<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating operations up to 1200 \u00b0C<\/td>\n            <td data-label=\"Echipament\">Fluidized bed heating equipment<\/td>\n            <td data-label=\"An\">2007<\/td>\n            <td data-label=\"Caracteristici echipament\">Operation in regime 50-600\u00b0C, optimal uniformity at 0.5\u00b0C, 2 heating elements of 750W, time to reach regime temperatures: 22min (600\u00b0C), 8 min (350\u00b0C), 6 min .(200\u00b0C), with Al2O3 salts 20lbs. Included, work space 6 in.H x 6.5 in. Dia, outside dimensions: 18 in.H x 13 in. Dia, power 240 VAC, weight 23.2 kg, fluidization with air at low pressure, in a dry environment<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating operations up to 1200 \u00b0C<\/td>\n            <td data-label=\"Echipament\">Particle fluidization drive pump<\/td>\n            <td data-label=\"An\">2007<\/td>\n            <td data-label=\"Caracteristici echipament\">Fluidization of salts with air at low pressure, power 230 VAC, 50Hz, Motor hp \u00bc<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating operations up to 1200 \u00b0C<\/td>\n            <td data-label=\"Echipament\">Electric furnace Neytech VULCAN<\/td>\n            <td data-label=\"An\">2007<\/td>\n            <td data-label=\"Caracteristici echipament\">Capacity 565cuin, operation in regime 200-1100\u00b0C, optimum uniformity 8\u00b0C, time to reach regime temperature: 60min(1100\u00b0C), working space 9 in.x 7 in.x9in., external dimensions: 15 13\/16 in.x16 x 17 in. , power 250 VAC, weight 27.7 kg, manually operated vertical door, with three stage programmable controller<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating operations up to 1200 \u00b0C<\/td>\n            <td data-label=\"Echipament\">Electric furnace BARNSTEAD<\/td>\n            <td data-label=\"An\">2007<\/td>\n            <td data-label=\"Caracteristici echipament\">Oval working space, capacity 908 cuin, operation in regime 200-1000\u00b0C, optimal uniformity 4\u00b0C, time to reach regime temperature: 120min (1100\u00b0C), power 1.48 KW, horizontally operated door manually, with controller programmable<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating operations up to 1200 \u00b0C<\/td>\n            <td data-label=\"Echipament\">Electric furnace NABERTHERM<\/td>\n            <td data-label=\"An\">2007<\/td>\n            <td data-label=\"Caracteristici echipament\">Capacity 5 L, operation in regime 200-1100\u00b0C, optimal uniformity 5\u00b0C, time to reach regime temperature: 60 min (1100\u00b0C), external dimensions: 440x420x523 cm, power 2.4 KW, manually operated horizontal door, with programmable controller type P320<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating \u2013 measuring temperature and control<\/td>\n            <td data-label=\"Echipament\">Infrared temperature measuring and recording chamber, with variable thermal profile<\/td>\n            <td data-label=\"An\">2008<\/td>\n            <td data-label=\"Caracteristici echipament\">128 storable images in JPG format; 3 different measurement possibilities: 64 checkered mosaic frames; 64 checkered frames; visible image; temperature range: -10 \u2013 1000\u00b0C; 64 measurement points; measured surface: 44 cm x 44 cm at a distance of 1 m; minimum measuring distance 0.5 m; compact flash memory: 128 MB; resolution: 0.1\u00b0C; accuracy: 2\u00b0C<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating \u2013 measuring temperature and control<\/td>\n            <td data-label=\"Echipament\">Thermal data acquisition system 8 channels<\/td>\n            <td data-label=\"An\">2008<\/td>\n            <td data-label=\"Caracteristici echipament\">Includes software for Windows and RS232<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating \u2013 measuring temperature and control<\/td>\n            <td data-label=\"Echipament\">Set of temperature measuring elements, type K<\/td>\n            <td data-label=\"An\">2008<\/td>\n            <td data-label=\"Caracteristici echipament\">The set includes a number of 18 type K samples, namely:\n1. Standard, 4\"L. Includes 5-ft cable. Ideal for soft materials, code AK-08516-65 K \u2013418 to 1650 (\u2013250 to 899)<br>2. Low-cost, 2.5\"L. Includes 5-ft. cable, code BK-08439-82 K \u2013418 to 1650 (\u2013250 to 899)<br>3. Small-diameter with hypodermic type, 4\"L. Includes 5-ft cable, code K-93601-04 K \u2013418 to 1500 (\u2013250 to 816)<br>4. Heavy-duty, 12\"L. Includes 5-ft cable. Ideal for frozen and soft materials. code K-93601-24 K \u2013418 to 1652 (\u2013250 to 900)<br>5. Heavy-duty, 10\"L. Includes 5-ft cable and stainless steel T-shape. code K-93601-84 K \u2013418 to 1652 (\u2013250 to 900)<br>6. Heavy-duty stainless steel, 6\"L. . Includes 5-ft. cable, code K-08517-67 J \u2013310 to 1400 (\u2013190 to 760) Junction: grounded<br>Each thermocouple has a maximum response time of 30 seconds and is equipped with 316 SS mini-connectors.<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating \u2013 measuring temperature and control<\/td>\n            <td data-label=\"Echipament\">IR temperature probe InfaPro Infrared Thermometers<\/td>\n            <td data-label=\"An\">2006<\/td>\n            <td data-label=\"Caracteristici echipament\">Measuring range: from -32\u00b0C to 535\u00b0C, resolution 0.2\u00b0C, response time 500msec, class II laser, digital display with Hold, Max and Scan indication<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Heating \u2013 measuring temperature and control<\/td>\n            <td data-label=\"Echipament\">Termoanemometru Datalogging Vane<\/td>\n            <td data-label=\"An\">2006<\/td>\n            <td data-label=\"Caracteristici echipament\">Recording up to 1000 points, with dual display - line, 4 digit LCD and RS 232 interface, simultaneous recording of pipe diameter - temperature - speed, accuracy: 3%,<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Other equipment<\/td>\n            <td data-label=\"Echipament\">Water bath 12L, Phoenix Instrument<\/td>\n            <td data-label=\"An\">2024<\/td>\n            <td data-label=\"Caracteristici echipament\">Fast heating time and maximum working temperature of up to 99 \u00b0C. \nThe water bath is equipped with a water drain tap.<br>Volume: 12 liters, Temperature range: 2 5\u00b0C\u202699\u00b0C, Display resolution: 0.1 \u00b0C, Temperature homogeneity at 37\u00b0C: \u00b10.5 \u00b0C Temperature deviation at 37\u00b0C: \u00b10.1 \u00b0C, Overheating protection: yes, Timer: 99:59\/continuous, Base plate dimensions: 290 x 230 mm, Max. number of modules: 4, Minimum height when closed Lid: 150 mm Voltage\/Power: 230V \/ 900W, External dimensions (WxHxD): 480 x 380 x 310 mm, Weight: 12 kg, Safety class: 2<\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Simulation<\/td>\n            <td data-label=\"Echipament\">CFD simulation with ANSYS workbench<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\"><\/td>\n        <\/tr>\n        <tr>\n            <td data-label=\"Tip test\">Data analysis<\/td>\n            <td data-label=\"Echipament\">Data analysis under MATLAB<\/td>\n            <td data-label=\"An\">2025<\/td>\n            <td data-label=\"Caracteristici echipament\"><\/td>\n        <\/tr>\n    <\/tbody>\n<\/table>\n\n\n\n<p><\/p>\n<style class=\"advgb-styles-renderer\">\n        body {\n            font-family: Arial, sans-serif;\n            margin: 20px;\n            background-color: #f4f4f9;\n        }\n        table {\n            width: 100%;\n            border-collapse: collapse;\n            box-shadow: 0 2px 3px rgba(0,0,0,0.1);\n            background-color: #fff;\n        }\n        th, td {\n            border: 1px solid #dddddd;\n            text-align: left;\n            padding: 12px;\n            vertical-align: top;\n        }\n        thead {\n            background-color: #e9ecef;\n            color: #333;\n        }\n        tbody tr:nth-child(even) {\n            background-color: #f9f9f9;\n        }\n        tbody tr:hover {\n            background-color: #f1f1f1;\n        }\n\n        \/* === STILURI MODIFICATE PENTRU MOBIL === *\/\n        @media screen and (max-width: 768px) {\n            thead {\n                display: none; \/* Ascunde header-ul tabelului *\/\n            }\n            tr {\n                display: block;\n                margin-bottom: 20px;\n                border: 1px solid #ccc;\n                border-radius: 5px;\n                padding: 15px;\n                box-shadow: 0 1px 2px rgba(0,0,0,0.1);\n            }\n            td {\n                display: block; \/* Fiecare celul\u0103 devine un r\u00e2nd *\/\n                text-align: left; \/* Textul este aliniat la st\u00e2nga *\/\n                border: none;\n                padding: 8px 0;\n            }\n            td:not(:last-child) {\n                border-bottom: 1px solid #eee; \/* Linie de separare \u00eentre c\u00e2mpuri *\/\n            }\n            td:before {\n                \/* Adaug\u0103 eticheta la \u00eenceputul textului *\/\n                content: attr(data-label) \": \";\n                font-weight: bold;\n                \/* Nu mai folosim pozi\u021bionare absolut\u0103, eticheta curge natural cu textul *\/\n            }\n        }\n    <\/style>","protected":false},"excerpt":{"rendered":"<p>Servicii: Echipamente \u015fi caracteristici Tip test Echipament An Caracteristici echipament C\u00e2nt\u0103rirea probelor Balan\u021ba analitic\u0103 Kern KERN ADJ 100-4 2023 Precizie de citire -0.001 g; devia\u021bie standard &#8211; 0.0001g; dimensiuni platan &#8211; \u00f8 90 mm; calibrare-intern\u0103; timp de stabilizare &#8211; 4.0s; domeniul maxim de c\u00e2nt\u0103rire este de &#8211; 120 g; prezinta picioare de nivelare pentru a [&hellip;]<\/p>","protected":false},"author":2,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"advgb_blocks_editor_width":"","advgb_blocks_columns_visual_guide":"","footnotes":""},"class_list":["post-42","page","type-page","status-publish","hentry"],"coauthors":[],"author_meta":{"author_link":"https:\/\/atnano.sim.tuiasi.ro\/en\/author\/bogdan_atnano\/","display_name":"Bogdan_atnano"},"relative_dates":{"created":"Posted 1 year ago","modified":"Updated 6 months ago"},"absolute_dates":{"created":"Posted on January 22, 2025","modified":"Updated on October 16, 2025"},"absolute_dates_time":{"created":"Posted on January 22, 2025 2:57 pm","modified":"Updated on October 16, 2025 12:27 pm"},"featured_img_caption":"","featured_img":false,"series_order":"","_links":{"self":[{"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/pages\/42","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/comments?post=42"}],"version-history":[{"count":8,"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/pages\/42\/revisions"}],"predecessor-version":[{"id":187,"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/pages\/42\/revisions\/187"}],"wp:attachment":[{"href":"https:\/\/atnano.sim.tuiasi.ro\/en\/wp-json\/wp\/v2\/media?parent=42"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}